  Pump is a device that moves the fluid some times slurry by the mechanical action,typically converted from electrical energy to hydraulic energy. Pumps can be classified into two major group by there action of moving fluid Direct lift and displacement.

Types of Pumps

 The pumps are mainly classified in two basic types Dynamic pumps and positive displacement pumps


1)Dynamic Pumps:- Dynamic pumps classified in lot of types but we are going to discus some of them like centrifugal pumps.

Centrifugal Pumps:-These types of Pumps are most commonly used in worldwide.The working is simple,described well and carefully tested.This pumps are strong,efficient and cheap to make.Centrifugal pumps are transport fluid by conversion of rotating energy into kinetic energy of fluid.




2) Positive Displacement pumps:- Positive Displacement pumps classified into lots of types but we are going to discuss about Diaphragm pump.

Diaphragm Pump:-These pumps are also known as a AODD(Air operated Double Diaphragm)pumps.These pumps are responding pumps and include two Diaphragm driven by compressed air.These pumps are used to transport Chemical,food manufacturing,underground coal mine.




Comments

  1. We provide all heat pump services at reasonable rates, whether it's installation, replacement, or heat pump repair in Stony Brook, NY. Get your heat pump fixed by our well-trained and qualified technicians. Call 631-928-1250 to know more about our services.

    ReplyDelete

Post a Comment

Popular posts from this blog

How to control Temperature and Humidity in Air Handling Unit

  How to control Temperature and Humidity in Air Handling Unit Overview Air Handling unit is a system used to supply temperature and Humidity controlled filtered air to the cleanroom. For air filtration various types of filters are used in AHU. And for temperature and Humidity controlling cooling and heating coils are provided in AHU. Goals Control the temperature of air used in the cleanroom  Control the humidity of air used in cleanroom  Air filters Specifications    The air Handling unit consists of Air filter  Cooling coil Heating coil Air blower HEPA Filter  Controlling of Temperature and Humidity  By Cooling Method  The cooling coil recirculates the chilled water having temperatures between 4°C to 6°C. This chilled water comes from the Chiller through centrifugal pumps. When we start the Air Handling unit blowers sucks the air through the pre filters of the air Handling unit. When blowers sucks air, it passes through the cooling co...

AIR FLOW, AIR VELOCITY, ACPH, AHU CAPACITY

Air Changes per Hour AIR VELOCITY AND ACPH OF ROOM OR AREA   Procedure to be followed: Air Velocity Measurement and Calculation of Air Changes: Objective : To demonstrate  that the   air system is balanced and capable of delivering air velocities and providing number of air changes per hour in the respective rooms as   per requirement. Equipment to be used: Hotwire Anemometer or capture Hood Pre Requisite: Air Volumes through supply and return grills and filters should be adjusted as per the design requirement of Air Change Rate and Differential Pressure. Test Method : Ensure that the Supply blower of the AHU is "ON" prior to the start of the observations. For compliance of air change rate, velocity to be measured at 5   different locations to below the each terminal or Grill (Four Corners and center) with the help of calibrated Anemometer. Calculate the   average  velocity of the air coming from Plenum HEPA filter / supply air grill. Calculate the air...

Why ice forms at cooling coil and Suction line in Refrigeration system

 Why ice forms at cooling coil and Suction line in Refrigeration system       it's all about the relationship between a temperature and pressure and how the pressure affect the boiling point of the refrigerant. As the pressure of refrigerant increases then the temperature and boiling point also increases,  when pressure decreased temperature and boiling point also decreases. Refrigeration and air conditioning systems take use of it to cool the air or liquid.   Normal Refrigeration System      In normal refrigeration system compressor compresses the refrigerant which causes the increase in pressure and temperature of refrigerant. The hot vapour refrigerant pass through the condenser in condenser heat exchange happens and refrigerant condensate into liquid forms.Before entering in the evaporator high pressure liquid refrigerant pass through the expansion of valve. The actual device used depends on the Refrigeration system but capillary t...