Design of HVAC system and Component

DESIGN Of HVAC SYSTEMS AND elements


HVAC systems ought to be suitably designed and managed throughout their life cycle. 

Documentation like schematic drawings ought to be maintained to replicate this state of affairs, together with however not restricted to, air offer and extraction,air Handling units,room pressure cascades,air flow direction, personnel and material movement,and waste removal.

Risk management principles ought to be applied throughout the planning of AN HVAC system. 

This includes,but isn't restricted to, acceptable controls of the climate and also the presentation of contamination and cross-contamination.

The HVAC system capability ought to be enough to confirm that the desired Performance is maintained throughout traditional use. 

Materials of construction for elements of AN HVAC system shouldn't become a supply of contamination. 

Where potential, Ducting, piping, fittings sensors and different elements ought to be clearly marked or tagged for easy identification, location and direction of flow as acceptable. 


Air intake and exhaust air terminals ought to be positioned in an exceedingly manner in regard to each other that assist in preventing cross-contamination. 

Air-handling units (AHUs) ought to be supplied with adequate drains to get rid of atmospheric phenomenon which will type within the AHU

Conditions and limits for parameters like temperature, ratio, air cleanliness and recovery times ought to be mere and achieved,as needed, for the materials and merchandise handled,as can as method Risks. 

Room recovery rates ought to demonstrate that the HVAC system is capable of returning a region to a mere level of cleanliness or classifications, temperature, ratio,room pressure and microbic limits, as acceptable inside the required time. 

Possible space pressure changes because of fan failure and partial system stop working with an effect on easy gap of doors for escape functions ought to be thought-about.
The effectiveness of the air distribution and air flow patterns ought to be acceptable and effective. 

Air offer and extract grilles ought to be suitably situated to supply effective space flushing and stop zones of stagnant air. 
The Performance of HVAC systems ought to be controlled and monitored to confirm in progress compliance with outlined parameters. Records ought to be maintained. Limits outlined ought to be even. 

Where automatic observance systems ar used, these ought to be capable of indicating ANy out - of - Specifications (OOS) condition by means that of an alarm or similar system. wherever these systems ar known as GXP systems. they must be suitably valid. 

Appropriate alarm systems ought to be in situ to alert personnel just in case vital element of the system fails, e.g. a fan.
The result of fan failure on building and HVAC elements ought to be assessed wherever acceptable provision ought to be created for a devotee interlock failure matrix. 

Switching off of AHUs at intervals like long or weekend, or reducing offer air volumes throughout non-production hours, shouldn't compromise product quality wherever this is often done, there ought to be acceptable justification and no risk to materials or merchandise. The procedure and satisfactoriness ought to be tried through Validation and qualification.

There ought to be  procedures and records maintained for the beginning up and stop working sequence of air Handling units.

Comments

  1. Wow, cool post. I’d like to like this too – taking time and real hard work to make a great article… but I put things off too much and never seem to get started. Thanks though. Air Temp Control

    ReplyDelete
  2. This is a great inspiring article.I am pretty much pleased with your good work.You put really very helpful information. Keep it up. Keep blogging. Looking to reading your next post.
    Air Temp Control

    ReplyDelete
  3. Nice post. I was checking this blog and I am impressed! Extremely helpful information specially the last part I care for such info a lot. I was seeking this particular information for a very long time. Thank you and good luck. Air conditioning Repair In Parker SC

    ReplyDelete
  4. This blog provides great information about the benefits of HVAC Company. Monster air is one of the best HVAC Company. We offer one of the best all HVAC service in Queen Creek. It is essential to ensure that our HVAC system is working fine.

    ReplyDelete

Post a Comment

Popular posts from this blog

How to control Temperature and Humidity in Air Handling Unit

  How to control Temperature and Humidity in Air Handling Unit Overview Air Handling unit is a system used to supply temperature and Humidity controlled filtered air to the cleanroom. For air filtration various types of filters are used in AHU. And for temperature and Humidity controlling cooling and heating coils are provided in AHU. Goals Control the temperature of air used in the cleanroom  Control the humidity of air used in cleanroom  Air filters Specifications    The air Handling unit consists of Air filter  Cooling coil Heating coil Air blower HEPA Filter  Controlling of Temperature and Humidity  By Cooling Method  The cooling coil recirculates the chilled water having temperatures between 4°C to 6°C. This chilled water comes from the Chiller through centrifugal pumps. When we start the Air Handling unit blowers sucks the air through the pre filters of the air Handling unit. When blowers sucks air, it passes through the cooling co...

Why ice forms at cooling coil and Suction line in Refrigeration system

 Why ice forms at cooling coil and Suction line in Refrigeration system       it's all about the relationship between a temperature and pressure and how the pressure affect the boiling point of the refrigerant. As the pressure of refrigerant increases then the temperature and boiling point also increases,  when pressure decreased temperature and boiling point also decreases. Refrigeration and air conditioning systems take use of it to cool the air or liquid.   Normal Refrigeration System      In normal refrigeration system compressor compresses the refrigerant which causes the increase in pressure and temperature of refrigerant. The hot vapour refrigerant pass through the condenser in condenser heat exchange happens and refrigerant condensate into liquid forms.Before entering in the evaporator high pressure liquid refrigerant pass through the expansion of valve. The actual device used depends on the Refrigeration system but capillary t...

HVAC Validation In pharma Industries

HVAC VALIDATION As per ISO guidelines for HVAC validation. In HVAC Validation  below points are determined and validated that they are in within range as per designed which will pass the respective ISO standard class acceptance criteria. 1)Air velocity and CFM calculation 2)Air changes per hour 3) Installed filter leakage test 4) HEPA filter integrity test 5)Air flow pattern test or smoke test 6)Partical count test 7)Total variable count 8) Temperatur and pressure monitoring 9) Temperature and Humidity recovery test 10) Fresh air calculation All this points are determined recorded in documents.All this validation process done by validation contractors under observation of respective company Engineer. 1) Air velocity and CFM calculation :-   - Scan the area of the HEPA filter with probe of anemometer 6 inches from the filter face. - For accurate velocity take the velocity of air at five place of filters ( Four corners and centre of filter) - Record the air velocity i...