Industrial Chiller on Vapour compression refrigeration cycle

Industrial Chiller


1)What is Chillar:-Industrial process chiller is a machine which remove heat from liquid by vapour Compression,absorption and adsorption cycle.
This Chilled liquid further used for cooling in Air Handling unit, For Reactor,For heat exchanger and for lots of equipment who's need to be cool.


Industrial Process Water Chiller 

     We are going to see Industrial process Water Chiller on a vapour compression cycle,Chiller maintain temperature of water at 4℃, this Chilled water required in Air Handling unit for maintaining temperature and humidity of Air.



2)Main components of Chiller:-
In every chiller there are four most important parts are Compressor,Condenser,Expansion valve and Evaporator.

-Compressor:- When we start the chiller compressor compress the vapour Refrigerant Due to the compression, pressure and temperature of vapour Refrigerant increases. Compressor circulates the Refrigerant through the all system, there is no any equipment used for refrigerant circulation through system. 

-Condenser:- After compressor high pressure and high temperature vapour Refrigerant comes in condenser. Cooling water provided for condenser for cooling.When Refrigerant inters in condenser heat exchange done between cooling water and refrigerant.Cooling water remove heat from refrigerant.Due to Cooling of refrigerant,it condensate in condenser and found a liquid form.
-Expansion Valve:- After condenser high pressure and low temperature liquid Refrigerant pass through expansion valve.In expansion valve expansion of refrigerant happens which means the sudden pressure drop happens in expansion valve.Due to the pressure dropping of liquid refrigerant it's temperature also decreases because the property of gases when gas pressure suddenly decrease then temperature also decreases.
-Evaporator:- Then low temperature and low pressure liquid refrigerant comes in evaporator.In evaporator water is provided which is to be Chilled.When refrigerant inters in evaporator again pressure drop of refrigerant happens because in the evaporator the volume of refrigerant flowing line is more than the before evaporator refrigerant flowing line.Due to increase in volume,pressure again decreases of refrigerant and refrigerant found a vapour state.Then heat exchange done between low temperature refrigerant and water.The low temperature of refrigerant gained by water.
    After evaporator low temperature low pressure vapour Refrigerant comes in a compressor.Then again this cycle continues.

Overview 

  Apart from that four main component of Process Chiller some another component also used for more efficient of Chiller like Subcooler, oil separator, oil cooler, primary expansion valve with heat exchange. 
Tip: Subcooler and primary expansion valve with heat exchange are used in brine Chiller where temperatures maintained in a -°C.
   

Comments

  1. Thank you for this valuable information. welcome to Arctic Mount

    ReplyDelete
  2. Thanks for the insightful and knowledgable post about chiller. We at Senho are committed towards manufacturing and selling quality industrial chiller. Keep up the excellent work and check us out.
    SenhoMachinery

    ReplyDelete
  3. i enjoyed a lot
    چیلر جذبی از یک ابزوربر یا جذب­‌کننده برای ماده­ی اصلی کار خود استفاده می‌کند. نمک از بهترین جذب­‌کننده­‌ها برای این کار است و لیتیوم بروماید یکی از بهترین گزینه‌­ها برای این کار شناخته شده است. بنابراین در چیلرهای جذبی مخزنی برای نگهداری و عمل لیتیوم بروماید یا ماده­ی جاذب وجود دارد. علاوه بر مخزن ابزوربر یا جذب­کننده، از پمپ و ژنراتور یا مبدل حرارتی هم درون چیلرهای جذبی استفاده شده است.

    ReplyDelete
  4. Maintaining industrial cooling towers isn’t an easy task if you don’t know much about them.
    With a little knowledge, you can make this task simple and efficient for yourself. By proper maintenance, you can enhance the performance and longevity of your chiller as well.
    Just follow these tips to maintain your industrial chiller:
    Regular Inspection
    The fundamental method to maintain your industrial cooling tower is to inspect it regularly. From the gearbox to the water pump, you should do regular inspection to ensure there are no loose components.
    Regular inspection will also allow you to spot corrosion, scaling and other similar adverse issues.
    When you’ll find these issues before they escalate, you can get rid of them and keep your chiller in optimum condition.

    ReplyDelete

Post a Comment

Popular posts from this blog

How to control Temperature and Humidity in Air Handling Unit

  How to control Temperature and Humidity in Air Handling Unit Overview Air Handling unit is a system used to supply temperature and Humidity controlled filtered air to the cleanroom. For air filtration various types of filters are used in AHU. And for temperature and Humidity controlling cooling and heating coils are provided in AHU. Goals Control the temperature of air used in the cleanroom  Control the humidity of air used in cleanroom  Air filters Specifications    The air Handling unit consists of Air filter  Cooling coil Heating coil Air blower HEPA Filter  Controlling of Temperature and Humidity  By Cooling Method  The cooling coil recirculates the chilled water having temperatures between 4°C to 6°C. This chilled water comes from the Chiller through centrifugal pumps. When we start the Air Handling unit blowers sucks the air through the pre filters of the air Handling unit. When blowers sucks air, it passes through the cooling co...

Why ice forms at cooling coil and Suction line in Refrigeration system

 Why ice forms at cooling coil and Suction line in Refrigeration system       it's all about the relationship between a temperature and pressure and how the pressure affect the boiling point of the refrigerant. As the pressure of refrigerant increases then the temperature and boiling point also increases,  when pressure decreased temperature and boiling point also decreases. Refrigeration and air conditioning systems take use of it to cool the air or liquid.   Normal Refrigeration System      In normal refrigeration system compressor compresses the refrigerant which causes the increase in pressure and temperature of refrigerant. The hot vapour refrigerant pass through the condenser in condenser heat exchange happens and refrigerant condensate into liquid forms.Before entering in the evaporator high pressure liquid refrigerant pass through the expansion of valve. The actual device used depends on the Refrigeration system but capillary t...

HVAC Validation In pharma Industries

HVAC VALIDATION As per ISO guidelines for HVAC validation. In HVAC Validation  below points are determined and validated that they are in within range as per designed which will pass the respective ISO standard class acceptance criteria. 1)Air velocity and CFM calculation 2)Air changes per hour 3) Installed filter leakage test 4) HEPA filter integrity test 5)Air flow pattern test or smoke test 6)Partical count test 7)Total variable count 8) Temperatur and pressure monitoring 9) Temperature and Humidity recovery test 10) Fresh air calculation All this points are determined recorded in documents.All this validation process done by validation contractors under observation of respective company Engineer. 1) Air velocity and CFM calculation :-   - Scan the area of the HEPA filter with probe of anemometer 6 inches from the filter face. - For accurate velocity take the velocity of air at five place of filters ( Four corners and centre of filter) - Record the air velocity i...