Condenser

Condenser



Condenser is a device or unit used to condense a gaseous substance into a liquid state through cooling.In so doing,latent heat is released by substance and transferred to the surrounding environment.Condenser are used for efficient heat rejection in many industries.condenser comes in many sizes ranging from small to large industrial condenser.
 

Types of Condenser

Condenser has have three type on the basis of heat exchange.
    1)Air cooled.
    2)Water cooled
    3) Evaporative
Condenser have two more types on the basis of design
   1)Shell and tube condenser
   2)Tube in Tube condenser

Air cooled Condenser:- In this type of Condenser air is used as a cooling substance for condenser.Refrigerant pass through the tube.Tube is designed with the fins surrounding tube which allow more heat transfer because the fins hold the air more time around the tube.Becouse of that heat transfer done more effectively.
Fans are provided on condenser for air flow.



Water cooled Condenser:- In this type of Condenser shell and tube type condenser are used.In this cooling water from cooling tower used as a cooling substance.Cooling water flows through the tube and Refrigerant flows around the tube in shell.





Tube in Tube Condenser:-Tube in Tube condenser is also called a double-Tube condenser.Its name reflect it's design,The tube is placed inside the larger tube and the ends of the larger tube are sealed.In this type water flows from the inside the tube and Refrigerant flows in a larger tube.

  



Comments

Popular posts from this blog

How to control Temperature and Humidity in Air Handling Unit

  How to control Temperature and Humidity in Air Handling Unit Overview Air Handling unit is a system used to supply temperature and Humidity controlled filtered air to the cleanroom. For air filtration various types of filters are used in AHU. And for temperature and Humidity controlling cooling and heating coils are provided in AHU. Goals Control the temperature of air used in the cleanroom  Control the humidity of air used in cleanroom  Air filters Specifications    The air Handling unit consists of Air filter  Cooling coil Heating coil Air blower HEPA Filter  Controlling of Temperature and Humidity  By Cooling Method  The cooling coil recirculates the chilled water having temperatures between 4°C to 6°C. This chilled water comes from the Chiller through centrifugal pumps. When we start the Air Handling unit blowers sucks the air through the pre filters of the air Handling unit. When blowers sucks air, it passes through the cooling co...

AIR FLOW, AIR VELOCITY, ACPH, AHU CAPACITY

Air Changes per Hour AIR VELOCITY AND ACPH OF ROOM OR AREA   Procedure to be followed: Air Velocity Measurement and Calculation of Air Changes: Objective : To demonstrate  that the   air system is balanced and capable of delivering air velocities and providing number of air changes per hour in the respective rooms as   per requirement. Equipment to be used: Hotwire Anemometer or capture Hood Pre Requisite: Air Volumes through supply and return grills and filters should be adjusted as per the design requirement of Air Change Rate and Differential Pressure. Test Method : Ensure that the Supply blower of the AHU is "ON" prior to the start of the observations. For compliance of air change rate, velocity to be measured at 5   different locations to below the each terminal or Grill (Four Corners and center) with the help of calibrated Anemometer. Calculate the   average  velocity of the air coming from Plenum HEPA filter / supply air grill. Calculate the air...

HVAC Validation In pharma Industries

HVAC VALIDATION As per ISO guidelines for HVAC validation. In HVAC Validation  below points are determined and validated that they are in within range as per designed which will pass the respective ISO standard class acceptance criteria. 1)Air velocity and CFM calculation 2)Air changes per hour 3) Installed filter leakage test 4) HEPA filter integrity test 5)Air flow pattern test or smoke test 6)Partical count test 7)Total variable count 8) Temperatur and pressure monitoring 9) Temperature and Humidity recovery test 10) Fresh air calculation All this points are determined recorded in documents.All this validation process done by validation contractors under observation of respective company Engineer. 1) Air velocity and CFM calculation :-   - Scan the area of the HEPA filter with probe of anemometer 6 inches from the filter face. - For accurate velocity take the velocity of air at five place of filters ( Four corners and centre of filter) - Record the air velocity i...