Skip to main content

Industrial Cooling Tower

Cooling Tower




Cooling tower is a typical cooling methodology where air and water come into direct contact to reduce the temperature of the water. In this case, the temperature of the water flowing through the tower decreases by observing the air temperature while this process evaporate small amount of water.

Heated water from industrial processes or air-cooled condensers is pumped through pipes into the cooling water pipes. The water is sprayed through nozzles into objects called "collectors", which allow the water to flow through the cooling air and disperse as much water as possible into the water. As the water passes through the cooling tower, it is exposed to the air, which is drawn through the tower by fans driven by an electric motor. When water and air meet, a small amount of water evaporates and a cool atmosphere is created. The cooled water is then sent back to the condenser or workpiece where it absorbs heat. It must then be return supplied back to cooling tower to cool further.
 
Types:- 
 
2) Mechanical Draft cooling tower:-
 

  • In induced draft cooling towers, cooling tower placed at the upside of the tower, Fan draw the air upside through the PVC or wooden fills. The worm water is sprinkled over the fill from the top, and the air moves upward side through the fills, it evaporates small amount of the water.
  • In Forced draft cooling towers, Fans are fixed at the bottom of tower and air blown upward to the cooling tower through the fill. The worm water is sprinkled over the fills, and as the air moves upward, it cools the water through evaporation.
2) Natural draft cooling tower :- The hot water which is to be cooled comes from the heat exchanges pumped to top of  cooling tower by Pumps. Hot water spray nozzles connected in series to spray water from top which spray hot water from top and the fresh air is Induced by the open structure of cooling tower i.e. chimney due to pressure difference effect. That fresh air comes from the bottom of cooling tower. Heat exchange done between the fresh air and hot water. Some of the water is evaporated and cold water collected at the bottom of cooling tower.




History:-
     Cooling Tower oriented in 19th century through the development of condenser for steam engine. 

Comments

Post a Comment

Popular posts from this blog

How to control Temperature and Humidity in Air Handling Unit

  How to control Temperature and Humidity in Air Handling Unit Overview Air Handling unit is a system used to supply temperature and Humidity controlled filtered air to the cleanroom. For air filtration various types of filters are used in AHU. And for temperature and Humidity controlling cooling and heating coils are provided in AHU. Goals Control the temperature of air used in the cleanroom  Control the humidity of air used in cleanroom  Air filters Specifications    The air Handling unit consists of Air filter  Cooling coil Heating coil Air blower HEPA Filter  Controlling of Temperature and Humidity  By Cooling Method  The cooling coil recirculates the chilled water having temperatures between 4°C to 6°C. This chilled water comes from the Chiller through centrifugal pumps. When we start the Air Handling unit blowers sucks the air through the pre filters of the air Handling unit. When blowers sucks air, it passes through the cooling co...

Why ice forms at cooling coil and Suction line in Refrigeration system

 Why ice forms at cooling coil and Suction line in Refrigeration system       it's all about the relationship between a temperature and pressure and how the pressure affect the boiling point of the refrigerant. As the pressure of refrigerant increases then the temperature and boiling point also increases,  when pressure decreased temperature and boiling point also decreases. Refrigeration and air conditioning systems take use of it to cool the air or liquid.   Normal Refrigeration System      In normal refrigeration system compressor compresses the refrigerant which causes the increase in pressure and temperature of refrigerant. The hot vapour refrigerant pass through the condenser in condenser heat exchange happens and refrigerant condensate into liquid forms.Before entering in the evaporator high pressure liquid refrigerant pass through the expansion of valve. The actual device used depends on the Refrigeration system but capillary t...

HVAC Validation In pharma Industries

HVAC VALIDATION As per ISO guidelines for HVAC validation. In HVAC Validation  below points are determined and validated that they are in within range as per designed which will pass the respective ISO standard class acceptance criteria. 1)Air velocity and CFM calculation 2)Air changes per hour 3) Installed filter leakage test 4) HEPA filter integrity test 5)Air flow pattern test or smoke test 6)Partical count test 7)Total variable count 8) Temperatur and pressure monitoring 9) Temperature and Humidity recovery test 10) Fresh air calculation All this points are determined recorded in documents.All this validation process done by validation contractors under observation of respective company Engineer. 1) Air velocity and CFM calculation :-   - Scan the area of the HEPA filter with probe of anemometer 6 inches from the filter face. - For accurate velocity take the velocity of air at five place of filters ( Four corners and centre of filter) - Record the air velocity i...